Alarma: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Analogni izlazi: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Broj uzoraka: 1, 2, 4 or 8
Certificiranja: CE compliant / UL certified
Demineralised water: For rinsing
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimenzije (V x Š x D): 690 mm x 465 mm x 330 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garancija: 24 mjeseci
Granica detekcije: Calcium Hardness: ≤ 10 mg/L
Total Alkalinity: ≤ 20 mg/L
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferencija : Hardness: Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar.
Alkalinity: Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally.
Kalibracija: N.A.
Kivete: 20 - 30 minutes
40 minutes (+ Total Hardness Ca)
Klasa zaštite: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Kvaliteta uzorka: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Masa: 25 kg
Materijal: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Mjerna metoda: Acid-base titration (alkalinity only); Calmagite EDTA titration with LED dipping probe (combined)
Mjerni rang: Ca: 10 - 100 mg/L CaCO₃; Alk: 20 - 500 mg/L CaCO₃
  Calcium Hardness: 10 - 100 mg/L CaCO₃; Total Alkalinity: 20 - 500 mg/L CaCO₃
Napajanje: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Naziv metode: Titrimetric
Odvod: Atmospheric pressure, vented, min. Ø 32 mm
Parametar: Calcium Hardness; Total Alkalinity
Precision: Better than 2% full scale range for standard test solutions
Protok uzorka: 100 - 300 mL/min
Reagent Requirements: Keep between 10 - 30 °C
Temperatura prostora: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura uzorka: 10 - 30 °C
Uzorak: tlak: By external overflow vessel