Analogni izlazi:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Automatsko čišćenje:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Broj uzoraka:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Certificiranja:
CE, ETL certified to UL and CSA safety standards, UKCA
Demineralised water:
Internal dilution option: Rinse water & Dilution water
Digital outputs:
Profibus DP or Modbus RTU
Dimenzije (V x Š x D):
688 mm x 460 mm x 340 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garancija:
24 mjeseci
Granica detekcije:
No Dilution
0.001 - 0.05 mg/L Cr: 0.001 mg/L
0.002 - 0.125 mg/L Cr: 0.002 mg/L
0.003 - 0.25 mg/L Cr: 0.003 mg/L
0.005 - 0.5 mg/L Cr: 0.005 mg/L
Internal Dilution
0.025 - 2.5 mg/L Cr: 0.025 mg/L
0.05 - 5 mg/L Cr: 0.05 mg/L
0.125 - 12.5 mg/L Cr: 0.125 mg/L
0.25 - 25 mg/L Cr: 0.25 mg/L
0.375 - 37.5 mg/L Cr: 0.375 mg/L
0.5 - 50 mg/L Cr: 0.5 mg/L
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferencija :
Iron (III) (Fe3+), mercury (Hg2+) > 200 mg/L, molybdenum (Mo2+) > 200 mg/L, vanadium (V5+) > 5 mg/L. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Izlaz :
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Kalibracija:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Kivete:
No Dilution
Default: 10 min.
Continuous: 6 min.
Internal Dilution
Default: 15 min.
Continuous: 10 min.
Klasa zaštite:
IP44
Kvaliteta uzorka:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Masa:
Max. 35 kg
Materijal:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Mjerna metoda:
Diphenylcarbazide colorimetric method
Mjerni rang:
No Dilution
0.001 - 0.05 mg/L Cr
0.002 - 0.125 mg/L Cr
0.003 - 0.25 mg/L Cr
0.005 - 0.5 mg/L Cr
Internal Dilution
0.025 - 2.5 mg/L Cr
0.050 - 5 mg/L Cr
0.125 - 12.5 mg/L Cr
0.250 - 25 mg/L Cr
0.375 - 37.5 mg/L Cr
0.500 - 50 mg/L Cr
Napajanje:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Odvod:
Atmospheric pressure, vented, min. Ø 32 mm
Parametar:
Chromium, dissolved
Precision:
Better than 2% full scale range for standard test solutions
Protok uzorka:
100 - 300 mL/min
Reagent Requirements:
Keep color between 5 - 10 °C, all other between 10 - 30 °C
Releji:
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready (EZ9150)
Što je u pretincu:
EZ1009sc Chromium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour) and 1 x empty 5L Reagent Container with Fittings (for Buffer Solution)
Temperatura prostora:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura uzorka:
10 - 30 °C
Uzorak: tlak:
By external overflow vessel (open to atmospheric pressure)
Validation:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly